62
A26361-K881-Z102-4-7619
Operating and Indicator Elements
Preparation for Use and Operation
Indicators for hot-plug PCI slots
The indicators ((b) and (c) on figure 39 on page 95) are located on the card
guide on the inside of the server.
The indicators on these slots behave differently depending on whether (table 3)
or not the operating system supports hot-plug functionality (table 4 on page 63):
Pos.
Power
indicator
(green)
Error
indicator
(orange)
Status description
1
does not
light
does not
light
1. Device switched off.
2. Device operating but PCI slot not powered
up. One board may be installed or
removed.
2
flashing
does not
light
Device operating.
PCI slot is in enable or disable sequence.
Wait until the green LED has changed its
status (does not light after disable or lights
after enable sequence).
3
lights
does not
light
Device operating.
PCI slot powered up. No board may be
installed or removed.
4
does not
light
lights
Device operating: a problem has occurred.
There are two possible causes for this status:
–
The MRL sensor was pressed without
authorization. This status cannot be exited
(NMI initiated: see section “Hot-Plug PCI
Error Indicator Lighting” on page 76).
–
There was a power failure during the
enable sequence (the PCI slot is reset to
disable status).
Table 3: Operating system with hot-plug functionality: hot-plug PCI indicator modes