Setting Up the Floorstand Model
Hardware Installation
Ê
Unlock the server (1) and remove the key (figure 2 on page 27).
Ê
Slide up the accessible drives cover (2) as far as possible (2) until it engages
(approx. 0.5 cm above the closed position).
Ê
Hook the tabs of the HDD cover of into the recesses (3).
Ê
Push the top end of the HDD cover (4) in direction of the arrow until it
engages.
Ê
Set up the server.
V
CAUTION!
–
The device must be protected against direct sunlight.
–
The required minimum distances for operation and maintenance
areas (see “Maintenance area for the floorstand model” on
page 9) must be adhered to.
–
In order to connect other devices (e. g.: storage subsystem) the
rear of the server must be accessible.
–
The mains plug must be accessible easily and safely.
–
There must be a clearance of at least 200 mm in front of and
behind the server to ensure adequate ventilation.
Ê
Cabling the server. Please also refer to the section “Connecting Devices to
Server” on page 49 and section “Instructions on Connecting and Discon-
necting Cables” on page 52.
Ê
Connect the server to the power supply (see section “Connecting the Server
to the Line Voltage” on page 51).