TX300 S3
Options Guide
61
Accessible drives
Installing the FDD-DVD-LocalView box
V
CAUTION!
Keep the
section “Installing an accessible 5.25-inch drive” on
page 47
dummy cover for future use. If you remove the LocalView
module again and do not replace it with a new one, the dummy cover
must be reinstalled to comply with EMC regulations and to satisfy
cooling requirements and fire protection measures.
Ê
Slide the LocalView module into the mounting location until it latches in
place.
Ê
Attach the Con3 connector of the I
2
C cable (T26139-Y3718-V601) to the
connector on the rear of the LocalView module.
Ê
Close the server, connect it to the power outlet, and switch it on as described
in the
chapter “Completion” on page 79
ff.
I
Further information on operation and display modes is provided in the
documentation for the LocalView module.
8.5
Installing the FDD-DVD-LocalView box
In the third, lowest 5.25-inch bay a multibay (FDD-DVD-LocalView box) can be
installed.
Ê
Open the server and remove the front cover or rack front cover as described
in the in the
chapter “Preparation” on page 17
ff.
Ê
If a drive has been installed in the lowest 5.25-inch bay, remove the drive and
install it in a free 5.25-inch bay (see
section “Installing an accessible 5.25-
inch drive” on page 47
).