96
Upgrade and Maintenance Manual
TX120
S3
Basic software procedures
5.2.7
Enabling SVOM boot watchdog functionality
If ServerView Operations Manager boot watchdog functionality has been
disabled for firmware upgrade purposes (see section
5.1.2 on page 80
), it has
to be re-enabled to complete the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web frontend:
Configuring boot watchdog settings in the BIOS
Ê
Enter the BIOS.
Ê
Select the
Server Mgmt
menu.
Ê
Under
Boot Watchdog
set the
Action
setting to
Reset
.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.
Configuring boot watchdog settings using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Server Management
menu.
Ê
Under
Watchdog Settings
ensure that the check box next to Boot Watchdog is
selected. From the drop down list choose
Reset
and specify the desired
timeout delay.
Ê
Click
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.8
Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê
Enter the BIOS.
Summary of Contents for PRIMERGY TX120 S3
Page 6: ...Upgrade and Maintenance Manual TX120 S3 ...
Page 8: ...Upgrade and Maintenance Manual TX120 S3 Version history ...
Page 22: ...Upgrade and Maintenance Manual TX120 S3 Contents ...
Page 26: ...26 Upgrade and Maintenance Manual TX120 S3 Introduction ...
Page 48: ...48 Upgrade and Maintenance Manual TX120 S3 Important information ...
Page 110: ...110 Upgrade and Maintenance Manual TX120 S3 Basic software procedures ...
Page 244: ...244 Upgrade and Maintenance Manual TX120 S3 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual TX120 S3 System board and components ...
Page 418: ...418 Upgrade and Maintenance Manual TX120 S3 Cables Figure 276 Installed BBU in BBU holder ...
Page 422: ...422 Upgrade and Maintenance Manual TX120 S3 Cables ...