278
Upgrade and Maintenance Manual
TX120
S3
Accessible drives
12.2.3 Replacing an optical disk drive (ODD)
12.2.3.1 Required tools
●
Preliminary and concluding steps:
– Slotted screw driver (only for removing the optical disk ddrive filler cover
●
Installing accessible drives: tool-less
12.2.3.2 Preliminary steps
Before installing an accessible drive, perform the following steps:
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 79
.
Ê
Remove optical disk media from the drive.
Ê
Shut down the server as described in section
"Shutting down the server" on
page 58
.
Ê
Disconnect the AC power cord from the system.
Ê
Remove the server cover as described in section
"Opening the server" on
page 61
.
12.2.3.3 Replacing the optical disk drive
Ê
Remove the defective ODD as described in section
"Removing an optical
disk drive (ODD)" on page 273
.
Field Replaceable Units (FRU)
Average task duration: 15 minutes
Summary of Contents for PRIMERGY TX120 S3
Page 6: ...Upgrade and Maintenance Manual TX120 S3 ...
Page 8: ...Upgrade and Maintenance Manual TX120 S3 Version history ...
Page 22: ...Upgrade and Maintenance Manual TX120 S3 Contents ...
Page 26: ...26 Upgrade and Maintenance Manual TX120 S3 Introduction ...
Page 48: ...48 Upgrade and Maintenance Manual TX120 S3 Important information ...
Page 110: ...110 Upgrade and Maintenance Manual TX120 S3 Basic software procedures ...
Page 244: ...244 Upgrade and Maintenance Manual TX120 S3 Main memory ...
Page 362: ...362 Upgrade and Maintenance Manual TX120 S3 System board and components ...
Page 418: ...418 Upgrade and Maintenance Manual TX120 S3 Cables Figure 276 Installed BBU in BBU holder ...
Page 422: ...422 Upgrade and Maintenance Manual TX120 S3 Cables ...