67
PRIMERGY RX600 S3 User’s Guide
3
OS In
st
a
llation
U
sing ServerS
ta
rt
Configuring RAID
1
Select [Mass Storage Controller View] on the [Configuration for Disks and RAID
Controllers] window.
Click [Details]. As the default values are configured, confirm the settings and modify them as
necessary.
Add partitions as necessary.
`
Configure the setting as follows to configure RAID with the PG-142E3 card.
•For guided mode
Select the second [LSI/Mylex Raid Controller - MegaRAID SCSI32] from the list of [RAID
Controller].
•For preparation mode
Select [1] for [Controller number] in details settings.
`
One hot spare (standby disk) can be configured. When the hot spare disk is set to "Yes", set
the number of disk units to the number of installed disk units minus 1.
E.g.: When four hard disk units are installed, set the RAID level to "RAID5", and when the hot
spare disk is set to "Yes", set the number of disk units to "3".
Add a partition
1. Click [Add Partition].
A partition is added.
Add required partitions.