Starting up and operation
6.1.1.4
Indicators on the drives
Optical drive activity indicator
Lights up green when the storage medium is being accessed.
Hard disk drive indicators
Figure 11: Indicators on the 2.5-inch HDD modules
1 LED
green
HDD BUSY indicator (green)
– Lights up: HDD in active phase
– Does not light: HDD inactive (drive inactive)
2 LED
orange
HDD FAULT indicator (orange)
(in conjunction with a RAID controller)
– Does not light: no HDD error
– Lights up: HDD Faulty or Rebuild Stopped (drive
defective/needs replacing, a rebuild process was stopped or
the HDD module is not correctly inserted)
– Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
– Fast flashing: HDD Identify
– Four fast blinks/pause: HDD Predicted Fault
– Two fast flashes/pause: HDD Hot Spare (Hot spare drive
active. The corresponding drive has failed).