Choose one of the following options from the update tool menu to start the
iRMC update process:
Normal
:
Choose this option to update an existing system board.
Initial
:
Choose this option if the system board has been replaced prior to the iRMC
update procedure. This option will perform all relevant flash procedures in a
row, including the iRMC firmware and bootloader.
CAUTION
If the process is interrupted, the iRMC may be permanently
corrupted.
▶
Do not interrupt the iRMC upgrade process after it has started.
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
▶
After completion of the flash process, remove the USB stick and restart the
server.
iRMC recovery procedure
▶
Prepare an USB stick including the bootable iRMC firmware update image.
▶
Ensure that the server has been shut down and disconnected from the
mains, see
"Disconnecting the power cord (AC PSU)" on page 47
▶
Connect the USB stick containing the iRMC firmware to an USB port.
▶
Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
▶
Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
▶
Press the Power On/Off button. The system will start the POST process.
▶
During POST, press [F12] and select the connected USB stick as boot
device. The system will detect the USB stick.
Basic software procedures
RX4770 M6
Upgrade and Maintenance Manual
87
Summary of Contents for PRIMERGY RX4770 M6
Page 80: ...Basic hardware procedures 80 Upgrade and Maintenance Manual RX4770 M6 ...
Page 166: ...Hard disk drive HDD solid state disk SSD 166 Upgrade and Maintenance Manual RX4770 M6 ...
Page 298: ...Liquid cooling LC 298 Upgrade and Maintenance Manual RX4770 M6 ...
Page 314: ...Accessible drives 314 Upgrade and Maintenance Manual RX4770 M6 ...