594
Upgrade and Maintenance Manual
RX2540 M2
Appendix
I
Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
Pos.
Label
Indicator
Status
Description
1
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 595
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
ID
ID indicator,
see also
"iRMC-
related
status
signals" on
page 595
blue on
The server has been highlighted
using ServerView Operations
Manager, iRMC web frontend or the
ID button on the front panel for easy
identification
blue
flashing
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
2
[CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
For HDDs see also
prefailure detection" on page 595
orange
flashing
CSS component failure detected.
!
Summary of Contents for PRIMERGY RX2540 M2
Page 6: ...Upgrade and Maintenance Manual RX2540 M2 ...
Page 48: ...48 Upgrade and Maintenance Manual RX2540 M2 Before you start ...
Page 128: ...128 Upgrade and Maintenance Manual RX2540 M2 Basic software procedures ...
Page 142: ...142 Upgrade and Maintenance Manual RX2540 M2 Power supply unit PSU ...
Page 392: ...392 Upgrade and Maintenance Manual RX2540 M2 Processor CPU ...
Page 452: ...452 Upgrade and Maintenance Manual RX2540 M2 Accessible drives ...
Page 558: ...558 Upgrade and Maintenance Manual RX2540 M2 System board and components ...
Page 602: ...602 Upgrade and Maintenance Manual RX2540 M2 Appendix ...