222
Upgrade and Maintenance Manual
RX2540 M2
Hard disk drives (HDD) and solid state drives (SSD)
Figure 122: Connecting cables to SAS expander board
Ê
Connect SAS cables to the SAS expander board:
– (1) from backplane 1 connector X9 to SAS expander board connector
X10
– (2) from backplane 1 connector X10 to SAS expander board connector
X11
– (3) from backplane 2 connector X9 to SAS expander board connector
X12
– (4) from backplane 2 connector X10 to SAS expander board connector
X13
– (5) if applicable, from backplane 3 connector X9 to SAS expander board
connector X14
– (6) if applicable, from backplane 3 connector X10 to SAS expander board
connector X15
Ê
Connect the power cable to SAS expander board connector X3 (7).