134
Upgrade and Maintenance Manual
RX2540 M2
Power supply unit (PSU)
6.2.2
Removing the dummy cover
Figure 34: Removing the dummy cover
Ê
Press in on both release latches (1) and remove the dummy cover (2).
V
CAUTION!
Keep the dummy cover for future use. If a PSU is removed and not
immediately replaced by a new one, a dummy cover must be reinstalled
in the bay to comply with applicable EMC regulations and satisfy cooling
requirements.
6.2.3
Installing a hot-plug PSU
Figure 35: Folding up the handle
Ê
Push the handle of the PSU halfway upward in the direction of the arrow.