Update the BIOS or iRMC S6 firmware using the iRMC S6 web interface:
▶
Use the firmware version that is currently in operation.
▶
Make sure to update the firmware using the iRMC S6 web interface.
The firmware will not be saved to the iRMC microSD card when updating
using a bootable USB stick or updating using ASP.
▶
After the update is completed, check the SEL log files to verify if the update
was successful.
If the update is successfully completed, the following messages will be
recorded.
<iRMC>
A backup of iRMC Firmware %1 has been successfully created
on SD card.
<BIOS>
BIOS backup to SD card succeeded.
If the update fails and is not saved to the iRMC microSD card, a SEL stating
that it failed will be recorded.
Even if an error occurs during the saving process, the BIOS backup
image already saved on the iRMC microSD will not be lost.
15.6
M.2 SSD
15.6.1 Slots and bolts for M.2 SSDs
The system board offers two M.2 slots (Key M) with support for M.2 SSDs in
different lengths. With the M.2 SSD an internal SSD is offered. This SSD can
be configured as a boot device or data storage device.
System board and components
RX1330 M5
Upgrade and Maintenance Manual
311
Summary of Contents for PRIMERGY RX1330 M5
Page 68: ...Basic hardware procedures 68 Upgrade and Maintenance Manual RX1330 M5 ...
Page 118: ...Power supply unit PSU 118 Upgrade and Maintenance Manual RX1330 M5 ...
Page 178: ...Fans 178 Upgrade and Maintenance Manual RX1330 M5 ...
Page 230: ...Main memory 230 Upgrade and Maintenance Manual RX1330 M5 ...
Page 256: ...Accessible drives 256 Upgrade and Maintenance Manual RX1330 M5 ...
Page 282: ...Front panel 282 Upgrade and Maintenance Manual RX1330 M5 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M5 ...
Page 336: ...System board and components 336 Upgrade and Maintenance Manual RX1330 M5 ...
Page 362: ...Appendix A 362 Upgrade and Maintenance Manual RX1330 M5 ...
Page 403: ...14 RX1330M5S SERIAL ext Cable Plan CA05973 7065 PCIe SLOT2 System Board D3929 SERIAL ...
Page 405: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...