Service Supplement
PRIMERGY CX122 S1
Replacing the power supply unit
4.8
Replacing the power supply unit
Ê
Open the server as described in
section "Opening the server" on page 31
Ê
Remove all components except the power supply unit from the chassis as
shown in the related sections:
–
Heat sinks:
section "Removing a heat sink" on page 58
–
Processors:
section "Removing a processor" on page 60
–
Memory modules:
section "Removing a memory module" on page 73
–
Expansion cards:
section "Replacing expansion cards" on page 48
–
PCI riser card:
section "Replacing the PCI riser card" on page 53
–
System board:
section "Replacing the system board" on page 77
A pre-assembled replacement
chassis / PSU kit is available
under the following part
number:
S26361-K1378-V900
I
The CX122 S1 PSU
(460 W, open frame) is
not available as a
separate spare part.