BX600 S3
Operating Manual
13
Preface
Features
Power Supply
Up to four hot-swappable power supply units which adjust automatically to any
power voltage in the range 200 - 240 V in a 2+2 redundant power supply config-
uration ensure enough power for the system. If one of these units fails, the
others ensure that operation continues unimpaired. The defective power supply
unit can be replaced during operation (hot-swap).
Ventilation
The system is kept cool by three fans in each power supply unit and four single
fans, with two of them mounted one after the other in a housing in the rear
chassis. This configuration is redundant and hot-swappable.
High Level of Availability and Failure Protection
When memory data is accessed, 1-bit errors in the main memory are recog-
nized and automatically corrected with the ECC (Error Correcting Code)
method.
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the case of an error and automatically “hides” the defective system components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu
Technology Solutions analyzes and monitors all components relevant for
system reliability.
The hot-swappable components provide additional failure protection. Failure
protection on a complete blade system is ensured by up to four redundant, hot-
swap power supply units (PSU), as well as hot-swap, redundant fans.
Server Management
Server management is implemented via the supplied
ServerView
software and
PDA (Prefailure Detection and Analyzing) technology from Fujitsu Technology
Solutions. PDA warns of system errors or overloading before they occur so that
preventive measures can be taken.
ServerView
allows the management of all PRIMERGY servers in the network via
a central console. Here
ServerView
supports the following functions:
●
Remote startup (Wake On LAN)
●
Temperature monitoring of the CPU and the surrounding area