Preparation for use and operation
24
A26361-K423-Z202-3-7619
Performing the EISA configuration for the DAC
i
Detailed information on the EISA configuration program is provided in the
associated User's Manual.
Ê
Start the EISA configuration program.
Ê
You should make the following settings:
−
delayed drive switch on with six second spacing
−
Fast SCSI bus
−
You will find further settings in the User's Manual for the DAC.
Ê
Save the new settings.
Ê
Exit the EISA configuration program.
Creating a DOS system diskette for the DAC configuration
Ê
Create a DOS system disk with a minimum of system files.
Ê
Copy all the files from the DACCFG directory on the original disk
Configuration
and Utilities
onto the DOS system disk.
Ê
Keep the original disk in a safe place.
Performing DAC configuration
i
The procedure described only roughly in places below is described in
detail in the User's Manual for the Disk Array Controller.
Ê
Insert the newly created DOS system disk in the floppy disk drive and reboot
the server.
Ê
Start the DAC configuration program
DACCF
from the disk.
Ê
Set the
Fault Management
to
Enabled
.
(Main menu -->
Advance Functions
-->
Hardware Parameters
).
Ê
Divide the hard disks into physical packs.
Ê
Create one or more system drives.
Ê
Initialize the system drives.