5.3 Host Commands
C141-E145-02EN
5-21
final partial block is transferred. The number of sectors in the partial block to be
transferred is n where n = remainder of (“number of sectors”/”block count”).
If the READ MULTIPLE command is issued before the SET MULTIPLE MODE
command is executed or when the READ MULTIPLE command is disabled, the
device rejects the READ MULTIPLE command with an ABORTED COMMAND
error.
Figure 5.2 shows an example of the execution of the READ MULTIPLE
command.
•
Block count specified by SET MULTIPLE MODE command = 4 (number of
sectors in a block)
•
READ MULTIPLE command specifies;
Number of requested sectors = 9 (Sector Count register = 9)
Figure 5.2 Execution example of READ MULTIPLE command
At command issuance (I/O registers setting contents)
1F7
H
(CM)
1
1
0
0
0
1
0
0
1F6
H
(DH)
x
L
x
DV
Start head No. / LBA
[MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
Summary of Contents for MHR2010AT
Page 1: ...C141 E145 02EN MHR2040AT MHR2030AT MHR2020AT MHR2010AT DISK DRIVES PRODUCT MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 58: ...Theory of Device Operation 4 6 C141 E145 02EN Figure 4 3 Circuit Configuration ...
Page 188: ...Interface 5 114 C141 E145 02EN g d f f d e Figure 5 7 Normal DMA data transfer ...
Page 240: ...This page is intentionally left blank ...
Page 242: ...This page is intentionally left blank ...
Page 246: ...This page is intentionally left blank ...
Page 248: ...This page is intentionally left blank ...
Page 249: ......
Page 250: ......