Interface
5-28
C141-E042-01EN
After all sectors are verified, the last interruption (INTRQ for command
termination) is generated.
At command issuance (I/O registers setting contents)
1F7
H
(CM)
0
0
1
1
1
1
0
0
1F6
H
(DH)
×
L
×
DV
Start head No. /LBA
[MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
L
×
DV
End head No. /LBA
[MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No. / LBA [LSB]
00 (*1)
Error information
*1
If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.
(9) RECALIBRATE (X’1x’, x: X’0’ to X’F’)
This command performs the calibration. Upon receipt of this command, the
device sets BSY bit of the Status register and performs a calibration. When the
device completes the calibration, the device updates the Status register, clears the
BSY bit, and generates an interrupt.
This command can be issued in the LBA mode.
Summary of Contents for MHA2021AT
Page 1: ...C141 E042 01EN MHA2021AT MHA2032AT DISK DRIVES PRODUCT MANUAL ...
Page 40: ...Installation Conditions 3 12 C141 E042 01EN Figure 3 14 Example 2 of Cable Select ...
Page 45: ...4 3 Circuit Configuration C141 E042 01EN 4 5 Figure 4 2 Circuit Configuration ...
Page 51: ...4 6 Read write Circuit C141 E042 01EN 4 11 Figure 4 4 Read write circuit block diagram ...
Page 136: ...5 4 Command Protocol C141 E042 01EN 5 75 Figure 5 7 Normal DMA data transfer ...
Page 138: ...5 5 Timing C141 E042 01EN 5 77 Figure 5 8 Data transfer timing ...
Page 144: ...6 1 Device Response to the Reset C141 E042 01EN 6 3 Figure 6 1 Response to power on ...
Page 177: ......