Interface
5-56
C141-E042-01EN
At command completion (I-O registers setting contents)
1F7
H
(ST)
Status information
1F6
H
(DH)
×
×
×
DV
xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
Key-failure prediction status (C2h-2Ch)
Key-failure prediction status (4Fh-F4h)
xx
xx
Error information
The attribute value information is 512-byte data; the format of this data is shown
below. The host can access this data using the SMART Read Attribute Values
subcommand (FR register = D0h). The insurance failure threshold value data is
512-byte data; the format of this data is shown below. The host can access this
data using the SMART Read Attribute Thresholds subcommand (FR register =
D1h).
Table 5.8 Format of device attribute value data
Byte
Item
00
01
Data format version number
02
Attribute 1
Attribute ID
03
04
Status flag
05
Current attribute value
06
Attribute value for worst case so far
07 to 0C
Raw attribute value
0D
Reserved
0E to 169
Attribute 2 to
attribute 30
(The format of each attribute value is the same
as that of bytes 02 to 0D.)
16A to 16F
Reserved
170
171
Failure prediction capability flag
172 to 181
Reserved
182 to 1FE
Vendor specific
1FF
Check sum
Summary of Contents for MHA2021AT
Page 1: ...C141 E042 01EN MHA2021AT MHA2032AT DISK DRIVES PRODUCT MANUAL ...
Page 40: ...Installation Conditions 3 12 C141 E042 01EN Figure 3 14 Example 2 of Cable Select ...
Page 45: ...4 3 Circuit Configuration C141 E042 01EN 4 5 Figure 4 2 Circuit Configuration ...
Page 51: ...4 6 Read write Circuit C141 E042 01EN 4 11 Figure 4 4 Read write circuit block diagram ...
Page 136: ...5 4 Command Protocol C141 E042 01EN 5 75 Figure 5 7 Normal DMA data transfer ...
Page 138: ...5 5 Timing C141 E042 01EN 5 77 Figure 5 8 Data transfer timing ...
Page 144: ...6 1 Device Response to the Reset C141 E042 01EN 6 3 Figure 6 1 Response to power on ...
Page 177: ......