8. Electrical characteristics
Model name
ARHG72LHTA
ARHG90LHTA
Power supply
Voltage
V
230 ~
Frequency
Hz
50
Max operating current
A
4.6
6.0
Wiring spec. *1
Circuit breaker current
A
15
Power cable
mm
2
1.5
Connection cable *2
mm
2
1.5
Limited wiring
length
m
101
*1: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
As the regulations of wire size and circuit breaker differ in each country or region, select appropri-
ate devices complied to the regional standard.
*2: Limit voltage drop to less than 2%. Increase conductor size if voltage drop is 2% or more.
- 19 -