Chapter 8 Operational Settings
180
Example 2:
Position: Middle
Selected range = Enable, Start = 0 mm, End = 300 mm
Multifeeds are detected only within the area of light blue.
Example 3: (Bad Example)
Position: Middle
Selected range = Enable, Start = 100 mm, End = 102 mm
Since the detection range (length) is less than 5 mm,
multifeeds cannot be detected accurately.
HINT
When you use detection by overlapping, accuracy of multifeed detection
may drop if the documents are glued firmly or attached together by static
electricity.
35
300
Feed
Direction
Unit: mm
35
300
2
100
Unit: mm
Feed
Direction