10. Safety devices
Type of
protection
Protection form
Model
AOTG09LBCB
AOTG12LBCB
Circuit protection
Current fuse
(Near the terminal)
250 V, 20A
250V, 5 A
Current fuse
(PCB)
250 V, 15A
250V, 3.15 A
Fan motor
protection
Thermal protection
program
Activate
100±10°C
Fan motor stop
Reset
95±10°C
Fan motor restart
Compressor
protection
Thermal protection
program
(Discharge temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes