9. Electrical characteristics
*1: The maximum current is the total current of indoor unit and outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate
devices complied to the regional standard.
*3: Limit voltage drop to less than 2%. Increase conductor size if voltage drop is 2% or more.
Model name
AOTG09LBCB
AOTG12LBCB
Power supply
Voltage
V
240 ~
Frequency
Hz
50
Max. operating current*1
A
10.8
10.9
Starting current
A
3.9
5.3
Wiring spec.
*2
Circuit breaker current
A
16
Power cable
mm
2
2.5
Connection cable *3
mm
2
1.5
Limited wiring length
m
21