6-2. Heating capacity
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
Model: ARYG12LHTBP
Model: ARYG14LHTBP
Model: ARYG18LHTBP
AFR
m
3
/h
850
Indoor temperature
°CDB
16
18
20
22
27
Out
d
oo
r te
mp
er
at
ur
e
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
3.76
1.66
3.67
1.70
3.58
1.73
3.49
1.77
3.40
1.80
-10
-11
4.26
1.66
4.16
1.70
4.06
1.73
3.96
1.77
3.86
1.80
-5
-7
4.69
1.89
4.58
1.93
4.47
1.97
4.35
2.01
4.20
2.01
0
-2
5.30
1.93
5.17
1.97
5.05
2.01
4.92
2.01
4.76
2.01
5
3
5.79
1.92
5.65
1.97
5.51
2.01
5.38
2.01
5.18
2.01
7
6
5.99
1.83
5.85
1.87
5.70
1.91
5.56
1.95
5.42
1.98
10
8
6.05
1.81
5.91
1.85
5.76
1.89
5.62
1.92
5.47
1.96
15
10
6.08
1.78
5.93
1.82
5.79
1.86
5.64
1.90
5.50
1.94
20
15
5.87
1.58
5.73
1.61
5.59
1.65
5.45
1.68
5.31
1.71
24
18
5.86
1.56
5.72
1.59
5.58
1.63
5.44
1.66
5.30
1.69
AFR
m
3
/h
950
Indoor temperature
°CDB
16
18
20
22
27
Out
d
oo
r te
mp
er
at
ur
e
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
4.35
2.11
4.25
2.15
4.14
2.19
4.04
2.24
3.94
2.28
-10
-11
4.92
2.11
4.80
2.15
4.68
2.19
4.56
2.24
4.45
2.28
-5
-7
5.48
2.33
5.35
2.38
5.22
2.43
5.09
2.48
4.96
2.53
0
-2
6.29
2.50
6.14
2.55
5.99
2.60
5.84
2.66
5.69
2.70
5
3
7.04
2.65
6.88
2.71
6.71
2.76
6.46
2.76
6.17
2.76
7
6
6.83
2.29
6.66
2.34
6.50
2.39
6.34
2.43
6.18
2.48
10
8
7.08
2.34
6.91
2.39
6.74
2.43
6.57
2.49
6.40
2.54
15
10
6.71
2.01
6.55
2.05
6.39
2.08
6.23
2.14
6.07
2.18
20
15
6.28
1.60
6.13
1.63
5.98
1.67
5.83
1.70
5.68
1.74
24
18
6.47
1.60
6.32
1.63
6.16
1.67
6.01
1.71
5.85
1.74
AFR
m
3
/h
1,360
Indoor temperature
°CDB
16
18
20
22
27
Out
d
oo
r te
mp
er
at
ur
e
°CDB
°CWB
TC
IP
TC
IP
TC
IP
TC
IP
TC
IP
kW
kW
kW
kW
kW
-15
-16
5.17
1.96
5.04
2.00
4.92
2.04
4.80
2.09
4.67
2.12
-10
-11
5.85
2.11
5.71
2.16
5.57
2.21
5.44
2.25
5.30
2.29
-5
-7
6.54
2.22
6.39
2.26
6.23
2.31
6.07
2.36
5.92
2.41
0
-2
7.25
2.17
7.08
2.22
6.91
2.26
6.73
2.31
6.56
2.36
5
3
8.01
2.19
7.82
2.24
7.63
2.28
7.44
2.33
7.25
2.38
7
6
7.88
1.89
7.69
1.93
7.50
1.97
7.31
2.01
7.13
2.05
10
8
8.12
1.89
7.93
1.94
7.73
1.98
7.54
2.01
7.34
2.06
15
10
7.44
1.52
7.27
1.54
7.09
1.58
6.91
1.61
6.73
1.64
20
15
6.83
1.17
6.67
1.20
6.51
1.22
6.35
1.25
6.18
1.27
24
18
7.07
1.17
6.91
1.20
6.73
1.22
6.57
1.25
6.40
1.27
Summary of Contents for AOYG12LBLA
Page 27: ... 21 DUCT TYPE ARYG12 54LHTBP 5 2 Models ARYG30LHTBP ARYG36LHTBP ARYG45LHTBP and ARYG54LHTBP ...
Page 110: ... 104 OUTDOOR UNIT AOYG12 54LB 5 Wiring diagrams 5 1 Models AOYG12LBLA and AOYG14LBLA ...
Page 111: ... 105 OUTDOOR UNIT AOYG12 54LB 5 2 Models AOYG18LBCA and AOYG24LBCA 5 3 Model AOYG30LBTA ...
Page 112: ... 106 OUTDOOR UNIT AOYG12 54LB 5 4 Model AOYG36LBTA ...
Page 113: ... 107 OUTDOOR UNIT AOYG12 54LB 5 5 Models AOYG45LBTA and AOYG54LBTA ...