– 71 –
OPERATING TIPS
Temperature and Humidity Range
SPECIFICATION
MODEL
INDOOR UNIT
OUTDOOR UNIT
AST13PSA-W
AOT13PNA
TYPE
HEAT&COOL MODEL (REVERSE CYCLE) INVERTER
POWER
230V to 50Hz
COOLING
CAPACITY
3.7 (Minimum 1.03 to Maximum 4.0) kW
INPUT POWER
1.48 (Minimum 0.35 to Maximum 1.82) kW
CURRENT
6.5 (Maximum 8) A
HEATING
CAPACITY
4.85 (Minimum 0.8 to Maximum 6.1) kW
INPUT POWER
1.61 (Minimum 0.33 to Maximum 2.28) kW
CURRENT
7.1 (Maximum 10) A
MAX. PRESSURE
SUCTION
800kPa
DISCHARGE
2700kPa
REFRIGERANT
R22 950g
DIMENSIONS & WEIGHT
INDOOR UNIT
Height/Width/Depth
280/815/179 mm
Weight
9kg (NET)
OUTDOOR UNIT
Height/Width/Depth
535/695/250 mm
Weight
34kg (NET)
DB : DRY Bulb Temperature
Cooling and Dry
Heating
Indoor
Outdoor
Indoor
Outdoor
WB : Wet Bulb Temperature
DB
WB
DB
WB
DB
WB
DB
WB
Maximum Temperature
32
23
43
26
30
––
24
18
Minimum Temperature
18
13
10
––
2
––
– 5
– 6
• If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of
the indoor unit, and drip onto the floor or other objects underneath.
• If the air conditioner is used under higher temperature conditioner than those listed, the build-in protection cir-
cuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used
under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to
water leakage and other damage.
• Do not use this unit for any purpose other than the Cooling, Heating, and Dehumidifying, and air-circulation of
rooms in ordinary dwellings.
• The specifications listed in the above table were measured under the following conditions.
• Temperatures
• Position of the AIRFLOW DIRECTION flap
For ADJUSTING THE DIRECTION OF AIR CIRCULATION on Page 9, use position
w
for COOLING and
position
r
for HEATING.
COOLING
HEATING
DB
WB
DB
WB
Indoor Temp.
27
19
20
15
Outdoor Temp.
35
24
7
6
[°C ]
[°C ]