3-6. Water leaking
Forecast of cause
Erroneous installation
Drain hose failure
Diagnosis method when water leak occurs
Diagnosis method when water is spitting
out
•
Is main unit installed in stable condi-
tion?
•
Is main unit broken or deformed at the
time of transportation or maintenance?
Is the filter clogged?
•
Is drain hose connection loose?
•
Is there a trap in drain hose?
•
Is drain hose clogged?
Check gas pressure and cor-
rect it if there was a gas leak.
MPa
MPa
Is fan rotating?
End