![Fujitsu AOHG07KGCA Service Manual Download Page 114](http://html.mh-extra.com/html/fujitsu/aohg07kgca/aohg07kgca_service-manual_2344036114.webp)
¢
Temperature set back timer
• The SET BACK timer only changes the set temperature for 7 days, it cannot be used to start
or stop air conditioner operation.
• The SET BACK timer can be set to operate up to two times per day but only one temperature
setting can be used.
• During COOLING/DR↔ mode, the air conditioner will operate at a minimum of 18°C even if the
SET BACK temperature is set to 17°C or lower.
Case of SET BACK timer on the Cooling operation. (Setting temperature :22°C, SET BACK
temperature :26°C)
SET BACK setting
Operation
temperature
Operation
temperature
26°C
22°C
26°C
22°C
24°C
*1
ON
OFF
OFF
ON
*1: During the SET BACK function,
the setting temperature is changed.
Chenge the setting temperature:
22°C 24°C
5-2. →ired remote control
- (04-22) -
5. Timer operation control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for AOHG07KGCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 3 11 SR_CH01_AS069EG_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 3 11 SR_CH02_AS069EG_01 ...
Page 33: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS069EG_01 ...
Page 36: ......
Page 89: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS069EG_01 ...
Page 91: ...8 6 High temperature and high pressure release control heating mode 04 32 CONTENTS continued ...
Page 92: ......
Page 125: ...5 FILED WORKING 2022 03 25 SR_CH05_AS069EG_01 ...