Does not operate at all (Operation Lamp and Timer Lamp do not light up)
[Check Point]
(1) Is the input power voltage from the exclusive circuit AC outlet normal?
(2) Is the AC plug inserted to the AC outlet securely and not loose?
(3) Check if each connector is inserted securely.
[Checking Flow Chart]
Is AC input voltage from AC outlet normal ?
Is AC voltage between VA 1 normal?
Is DC voltage between terminal of C5 normal?
Is DC voltage between terminals of C7 and C12
Is DC voltage between terminal 1 & 2 of IC6 normal?
YES
(AC220/230V)
YES
(AC220/230V)
YES
(AC220/230V)
Is DC voltage between terminals of C9
YES
(C7:DC20V)
(C12:DC13.5
1V)
YES
(DC12 14V)
Terminal board temperature
fuse is blown or CN1 is loose
(IC2, T1 or IC3 defective)
IC4 defective
YES
(DC15V)
Is DC voltage between terminals 3 & 4 of IC7 normal?
YES (Pulse wave of DC5Vp-p)
IC7 defective
(F1, VA1 defective)
Input power supply failure
Controller PCB defective
NO
NO
NO
NO
NO
NO
NO
Switching power circuit
Switching power circuit
Switching power circuit
(F2, D1, R1 defective)
07-01
Summary of Contents for AO*12LFBC
Page 4: ...1 SPECIFICATIONS R410A WALL MOUNTED type INVERTER ...
Page 8: ...2 DIMENSIONS R410A WALL MOUNTED type INVERTER ...
Page 12: ...3 REFRIGERANT SYSTEM DIAGRAM R410A WALL MOUNTED type INVERTER ...
Page 16: ...4 CIRCUIT DIAGRAM R410A WALL MOUNTED type INVERTER ...
Page 20: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 40: ...6 REFRIGERANT CAUTION R410A R410A WALL MOUNTED type INVERTER ...
Page 46: ......
Page 47: ......
Page 70: ...9 INSTALLATION MANUAL R410A WALL MOUNTED type INVERTER ...
Page 83: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan GS17032005 March 2005 Printed in Japan ...