background image

En-13

8. 

Set the new or washed air cleaning 

fi

 lters into the air 

cleaning 

fi

 lter frames.

NOTES: 

Use the Apple-catechin 

fi

 lter as soon as possible after opening 

the package. The air cleaning e

 ect decreases when the 

fi

 lters 

are left in the opened package.

9. 

Install the air cleaning 

fi

 lter holders to the air 

fi

 lters.

Engage the 4 hooks at the rear of the air cleaning 

fi

 lter frame with 

the latch at both ends of the air 

fi

 lter.

* Take care that the air cleaning 

fi

 lter does not project beyond the 

frame.

Hook (4 places at the rear)

Latch (4 places)

NOTES: 

Take care that the air cleaning 

fi

 lter does not project 

beyond the frame.

10. 

Replace the air 

fi

 lters and close the intake grille. Refer to 

steps 4 ~ 5 of "Cleaning air 

fi

 lter".

Replacing Ion deodorization 

fi

 lter

1. 

Remove the air 

fi

 lters. Refer to steps 1 ~ 2

 

of "Cleaning air 

fi

 lter".

2. 

Remove the Ion deodorization 

fi

 lter (light blue) from the air 

cleaning 

fi

 lter holder.

3. 

Install the new Ion deodorizing 

fi

 lter.

Removing and installing intake grille

 

Removing intake grille

1. 

Open the intake grille.

2. 

While pressing the left and right mounting shafts outward 

gently, pull the intake grille.

 

Installing intake grille

1. 

While holding the intake grille horizontal, set the left and 

right mounting shafts into the pillow blocks at the top of the 

front panel.

Insert the shaft until it snaps to latch each shaft properly.

2. 

Close the intake grille.

3. 

Press 4 places on the intake grille to close it completely.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
Fan mode operation for half a day to dry the internal parts thoroughly 
before the normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

 Filter indicator reset (Special setting)

This function can be used if set correctly during installation. Please 
consult authorized service personnel in order to use this function.

Clean the air 

fi

 lter when the indicator lamp show the 

following:

Indicator lamp

Blinking pattern

 

 

Blinks 3 times, at intervals of 21 seconds

After cleaning, reset the 

fi

 lter indicator by pushing

 

 on the 

indoor unit for 2 seconds or less.

12. GENERAL  INFORMATION

 

Heating performance

This air conditioner operates on the heat-pump principle, absorbing 
heat from air outdoors and transferring that heat to the indoor unit. As a 
result, the operating performance is reduced as outdoor air temperature 
drops.
If you feel that the heating performance is insu

  cient, we recommend 

you to use this air conditioner in conjunction with other kinds of heating 
appliance.

 

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost may 
form on the outdoor unit during the heating operation, and it could 
reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic defrost 
function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and defrost circuit 
will operate brie

fl

 y (maximum of 15 minutes.)

[  ] indicator on the indoor unit blinks during this operation. 
If frost forms on the outdoor unit after the Heating operation, the outdoor 
unit will stop automatically after it operates for a few minutes. Then the 
Automatic defrosting operation starts.

 

 Auto-restart function

In event of power interruption such as a blackout, the air conditioner 
stops once. But it restarts automatically and performs previous operation 
when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of 
the timer will be reset. 
After the power supply is resumed, [   ] indicator on the indoor unit 
blinks to notify you that there has been a timer fault. In such a case, 
reset the clock and timer settings.

 

Malfunctions caused by other electrical 

devices

Use of other electrical appliances such as an electric shaver or nearby 
use of a wireless radio transmitter may cause the malfunction of the air 
conditioner. 
If you encounter such a malfunction, turn o

  the circuit breaker once. 

Then turn it on again, and resume operation by using the remote 
controller.

9387602098̲OM.indb   13

9387602098̲OM.indb   13

2022/09/26   19:41:42

2022/09/26   19:41:42

Summary of Contents for Airstage Wall Series

Page 1: ... mente y conserve este manual para consultarlo en el futuro Español Français English PART No 9387602098 02 MODE D EMPLOI CLIMATISEUR Type à montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future OPERATION MANUAL MODEL Please write down the model name Refer to the rating label Veuillez écrire le nom du modèle Consultez l étiq...

Page 2: ...he original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inlet port Do not operate with wet hands CAUTION Provid...

Page 3: ...ot attempt to recharge dry batteries Do not use dry batteries that has been recharged Indoor unit accessories Please check that the following accessories are included Remote controller Remote controller holder Tapping screws Batteries Air cleaning filters Filter holders Remote controller holder installation 3 2 1 Insert Screws Slide up 1 Before starting operation make sure that the intake grille i...

Page 4: ... deactivates the Economy operation Activates or deactivates the Energy saving program that uses the human sensor For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For Outdoor Unit Low Noise operation Refer to page 8 Activates or deactivates the Outdoor Unit Low Noise operation Remote controller display In t...

Page 5: ...erting batteries Battery type R03 LR03 AAA x 2 1 2 3 RESET 6 8 7 5 9 4 1 Pull the cover in the direction of the arrow and open it until it is trapped 2 Remove the cover Turn the remote controller over and push the back side of the cover and remove the claws by curving the cover Pull in the direction of the arrow while curving the cover 3 Put batteries as shown in the figure above 4 Press as shown ...

Page 6: ...e press again 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 1 F 0 5 C increments Temperature setting range Auto Cooling Dry 64 88 F 18 0 30 0 C Heating 60 88 F 16 0 30 0 C NOTES In the Cooling or D...

Page 7: ...ill run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day...

Page 8: ...view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature is high and the difference with people s body temperature is small Such as when the temperature is 86 F 30 C or higher in summer When someon...

Page 9: ...oom temperature at 50 F 10 C so as to prevent the room temperature to drop too low Press to activate the Min Heat operation The indoor unit will emit 1 short beep and indicator on the indoor unit will turn on Press to turn off the air conditioner indicator will turn off NOTES During the Min Heat operation only and are valid When the room temperature is warm enough this operation will not perform If ...

Page 10: ...that you must follow in relation to radio waves personal information and so on To use this product correctly be sure to read the following precautions and the operation manual of the wireless LAN equipment you are using We will assume no responsibility unless legal liability is recognized in regards to failures other defects and damages incurred by use of this product that occur through incorrect ...

Page 11: ...ff If you want to activate wireless LAN again select in step 2 Others Use this product as regular wireless LAN equipment Do not use this product in hospitals or in near locations with medical equipment Do not use this product within aircraft Do not use this product near electronic equipment that handles high precision control or weak signals Examples of electronic equipment to be careful of Hearing...

Page 12: ...nstalling or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Remove the W LAN adapter from the connection slot of the indoor unit in the direction as shown in the figure 5 Close the W LAN adapter cover and the intake grille 10 SETTINGS ON INSTALLATION 10 1 Remo...

Page 13: ...hinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake grille 2 Remove the air filters Lift up the air filters handle disconnect the two lower tabs and pull out Air filter handle Hooks 2 places 3 Remove the dust in either of the following ways Cleaning with vacuum cleaner...

Page 14: ...onsult authorized service personnel in order to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 12 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle ab...

Page 15: ...s the timer operating To check or deactivate the timer setting refer to page 5 Poor cooling or heating performance Is the unit operating under the conditions except the permissible temperature range In this case the air conditioner may stop because of the automatic protection circuit working Is the air filter dirty Clean the air filter Refer to page 12 Is the intake grille or outlet port of indoor...

Page 16: ... supports IEEE802 11b g n Check with the operation manual of the wireless router Check that the W LAN adapter of the indoor unit is on I am not able to operate this product from the mobile app Check that the power to the indoor unit is on Check that the power to the wireless router is on Check that your smartphone is not in flight mode Check that you are not in a place where it is difficult to make ...

Reviews: