1-2. Outdoor unit
Type
Inverter heat pump
Model name
AOYG09KVCBN
AOYG12KVCBN
AOYG14KVCBN
Power supply
230 V ~ 50 Hz
Available voltage range
198—264 V
Starting current
A
3.6
4.9
6.2
Fan
Airflow rate
Cooling
m
3
/h
1,550
1,830
2,210
Heating
1,690
2,100
2,100
Type × Q'ty
Propeller × 1
Motor output
W
49
Sound pressure level *1
Cooling
dB (A)
40
44
51
Heating
46
52
50
Sound power level
Cooling
dB (A)
54
58
63
Heating
58
62
63
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 588 × 881 × 18.19
Main2: 588 × 851 × 18.19
Fin pitch
1.3
Rows × Stages
2 × 28
Pipe type
Copper
Fin type
Type (Material)
Aluminium
Surface treatment
PC Fin
Compressor
Type × Q'ty
DC TWIN ROTARY
Motor output
W
810
925
Refrigerant
Type (Global warming potential)
R32 (675)
Charge
g
940
Refrigerant oil
Type
FW68S
RmM68AF
Amount
cm
3
350
400
Enclosure
Material
Steel sheet
Color
BEIGE
Dimensions
(H × W × D)
Net
mm
632 × 799 × 290
Gross
692 × 940 × 375
Weight
Net
kg
36
38
Gross
40
42
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 9.52 (Ø 3/8)
Method
Flare
Pre-charge length
m
15
Max.length
20
Max. height difference
15
Operation range
Cooling
°C
-10 to 46
Heating
-25 to 24
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m.
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
1-2. Outdoor unit
- (01-3) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Summary of Contents for AGYG09KVCB
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 10 05 SR_CH01_AG002EF_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 25 SR_CH02_AG002EF_02 ...
Page 37: ...3 TROUBLESHOOTING 2020 11 11 SR_CH03_AG002EF_01 ...
Page 39: ...5 1 Indoor unit 03 44 5 2 Outdoor unit 03 45 CONTENTS continued ...
Page 40: ......
Page 87: ...4 CONTROL AND FUNCTIONS 2020 11 11 SR_CH04_AG002EF_01 ...
Page 121: ...5 FILED WORKING 2020 11 11 SR_CH05_AG002EF_01 ...