1. Specifications
1-1. Indoor unit
Type
Floor type
Inverter heat pump
Model name
AGYG09KVCB
AGYG12KVCB
AGYG14KVCB
Power supply
230 V ~ 50 Hz
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
2.50
3.50
4.20
Btu/h
8,500
11,900
14,300
Min.—Max.
kW
0.9—4.3
0.9—4.3
0.9—5.2
Btu/h
3,100—14,700
3,100—14,700
3,100—17,700
Heating
Rated
kW
3.50
4.50
5.20
Btu/h
11,900
15,400
17,700
Min.—Max.
kW
0.9—5.5
0.9—6.2
0.9—6.3
Btu/h
3,100—18,800
3,100—21,200
3,100—21,500
Outdoor temp
-15°C
kW
3.7
4.5
5.2
Input power
Cooling
Rated
kW
0.51
0.83
1.06
Max.
1.65
2.11
2.11
Heating
Rated
0.81
1.1
1.41
Max.
1.65
1.98
1.98
Outdoor temp
-15°C
1.92
2.65
2.65
Current
Cooling
Rated
A
2.3
3.7
4.7
Heating
3.6
4.9
6.2
EER
Cooling
kW/kW
4.95
4.20
3.95
COP
Heating
4.32
4.10
3.70
Power factor
Cooling
%
96.4
97.5
98.1
Heating
97.8
97.6
98.9
Moisture removal
L/h (pints/h)
1.3 (2.3)
1.8 (3.2)
2.1 (3.7)
Maximum operating current *1
Cooling
A
9
11
11
Heating
10
12.5
12.5
Fan
Airflow rate
Cooling
HIGH
m
3
/h
570
570
650
MED
460
460
520
LOW
360
360
400
QUIET
270
270
270
Heating
HIGH
600
650
650
MED
480
480
520
LOW
370
370
390
QUIET
270
270
270
Type × Q'ty
Cross flow fan × 2
Motor output
W
16 × 2
Sound pressure level *2
Cooling
HIGH
dB (A)
40
40
44
MED
35
35
38
LOW
29
29
31
QUIET
22
22
22
Heating
HIGH
41
43
43
MED
35
35
37
LOW
29
29
29
QUIET
22
22
22
Heat exchanger type
Dimensions (H × W × D)
mm
378 × 550 × 26.6
Fin pitch
1.2
Rows × Stages
2 × 18
Pipe type
Copper tube
Fin type
Aluminium
Enclosure
Material
Polystyrene
Color
White
Dimensions
(H × W × D)
Net
mm
600 × 740 × 200
Gross
700 × 820 × 310
Weight
Net
kg
14
Gross
18
Connection pipe
Size
Liquid
mm (in)
Ø 6.35 (Ø 1/4)
Gas
Ø 9.52 (Ø 3/8)
Method
Flare
Drain hose
Material
PP + LLDPE
Size
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
30 or less
Remote controller type
Wireless (Wired, Mobile app*3 [FGLair
™
] [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
–
Measured values in manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
™
store or on App Store
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
1-1. Indoor unit
- (01-1) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Summary of Contents for AGYG09KVCB
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 10 05 SR_CH01_AG002EF_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 25 SR_CH02_AG002EF_02 ...
Page 37: ...3 TROUBLESHOOTING 2020 11 11 SR_CH03_AG002EF_01 ...
Page 39: ...5 1 Indoor unit 03 44 5 2 Outdoor unit 03 45 CONTENTS continued ...
Page 40: ......
Page 87: ...4 CONTROL AND FUNCTIONS 2020 11 11 SR_CH04_AG002EF_01 ...
Page 121: ...5 FILED WORKING 2020 11 11 SR_CH05_AG002EF_01 ...