5-2. Outdoor unit
¢
Discharge temperature thermistor
Temperature (°C)
Resistance (kΩ)
Voltage (V)
-30.0
1,000.13
0.06
-25.0
720.28
0.09
-20.0
525.51
0.12
-15.0
388.12
0.16
-10.0
289.97
0.21
-5.0
219.01
0.28
0.0
167.12
0.36
5.0
128.77
0.46
10.0
100.14
0.57
15.0
78.56
0.71
20.0
62.14
0.87
25.0
49.54
1.04
30.0
39.79
1.23
35.0
32.19
1.44
40.0
26.22
1.66
45.0
21.49
1.88
50.0
17.73
2.12
55.0
14.71
2.35
60.0
12.27
2.57
65.0
10.29
2.79
70.0
8.68
3.00
75.0
7.35
3.19
80.0
6.26
3.38
85.0
5.35
3.54
90.0
4.59
3.69
95.0
3.96
3.83
100.0
3.43
3.96
105.0
2.98
4.07
110.0
2.60
4.17
115.0
2.28
4.26
120.0
2.00
4.33