5. INDOOR FAN CONTROL
(1).Fan speed
( Table 5 : Indoor Fan Speed )
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
05-05
AG*V09/ 12LAC
Operation mode
Air flow mode
Speed (rpm)
Hi
1240/ 1040
1280/ ---
1040/ 880
1080/ ---
660/ 560
680/ ---
840/ 700
870/ ---
660/ 560
680/ ---
660/ 560
680/ ---
660/ 560
680/ ---
1190/ 1000
1230/ ---
1000/ 850
1030/ ---
820/ 690
850/ ---
---- / ----
680/ ---
Me
Lo
Heating
Quiet
Hi
Me
Lo
Quiet
Cool air prevention
S-Lo
Dry
Cooling
Fan
Upper& Lower
air flow mode
Upper
air flow mode
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
AG*V14LAC
Operation mode
Air flow mode
Speed (rpm)
Hi
1330/ 1120
1370/ ---
1100/ 930
1130/ ---
660/ 560
680/ ---
860/ 730
890/ ---
660/ 560
680/ ---
660/ 560
680/ ---
660/ 560
680/ ---
1330/ 1120
1370/ ---
1100/ 930
1130/ ---
890/ 750
890/ ---
---- / ----
680/ ---
Me
Lo
Heating
Quiet
Hi
Me
Lo
Quiet
Cool air prevention
S-Lo
Dry
Cooling
Fan
Upper& Lower
air flow mode
Upper
air flow mode
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
(Upper/ Lower)
Summary of Contents for AG * V12LAC Series
Page 4: ...1 SPECIFICATIONS R410A FLOOR type INVERTER ...
Page 6: ...2 DIMENSIONS R410A FLOOR type INVERTER ...
Page 9: ...3 REFRIGERANT SYSTEM DIAGRAM R410A FLOOR type INVERTER ...
Page 11: ...4 CIRCUIT DIAGRAM R410A FLOOR type INVERTER ...
Page 12: ...CIRCUIT DIAGRAM Models AG V09LAC AO V09LAC AG V12LAC AO V12LAC 04 01 INDOOR UNIT OUTDOOR UNIT ...
Page 13: ...CIRCUIT DIAGRAM Models AG V14LAC AO V14LAC 04 02 INDOOR UNIT OUTDOOR UNIT ...
Page 14: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A FLOOR type INVERTER ...
Page 35: ...6 REFRIGERANT CAUTION R410A R410A FLOOR type INVERTER ...
Page 62: ...9 REPLACEMENT PARTS R410A FLOOR type INVERTER ...
Page 80: ...10 INSTALLATION MANUAL R410A FLOOR type INVERTER ...
Page 89: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan May 2007 Printed in Japan ...