A26361-K879-Z102-3-7619
71
Problem Solutions and Tips
Drives ”dead“ at System Boot
7.10
Drives ”dead“ at System Boot
This error message may occur when the server has a RAID controller:
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives with the RAID controller utility.
Further information is provided in the manual on the RAID controller.
7.11
Added Drive Defective
This error message may occur when the server has a RAID controller:
RAID controller is not configured for this hard disk drive
The drive was installed with the system switched OFF.
Ê
Reconfigure the RAID controller for the drive with the corresponding utility.
Information is contained in the documentation on the RAID controller.
or
Ê
Re-insert the HDD module with the system switched ON into a free module
bay.
If the hard disk drive continues to be shown as defective, then replace it (see
section “Installing/Removing HDD/Dummy Module” on page 77).
7.12
Error Messages on the Monitor
The meanings of the error messages are explained in the manual for
BIOS Setup
and in the documentation for the relevant components and programmes on the
PRIMERGY ServerBooks CD.