Protocol
Please select protocol as DH-SD1 if you are using HDCVI mode.
Address
Set corresponding dome address. Default value is 1.
Please note
your setup here shall comply with your dome address; otherwise
you can not control the speed dome.
Baud
Rate
Select the dome baud rate. Default setup is 9600.
Data Bit
Default setup is 8. Please set according to the speed dome dial switch
setup.
Stop bit
Default setup is 1. Please set according to the speed dome dial switch
setup.
Parity
Default setup is none. Please set according to the speed dome dial
switch setup.
ATM/POS
The ATM/POS function is for financial areas. It includes Sniffer, information analysis and title overlay
function. The Sniffer mode is network.
The network type interface is shown as below. See Figure 4-72.
Here we take the ATM/POS protocol to continue.
There are two types: with or without the protocol according to client’s requirements.
With the protocol
For ATM/POS with the protocol, you just need to set the source IP, destination IP (s ometimes you need
to input corresponding port number).
Figure 4-72
Without the protocol
For the ATM/POS without the protocol, the interface is shown
Source IP refers to host IP address that sends out information (usually it is the device host.)
Destination IP refers to other systems that receive information.
Usually you do not need to set source port and target port.
There are total four groups IP. The record channel applies to one group (optional) only.
Six frame ID groups verification can guarantee information validity and legal.