62S_Rev3
95
Questions and Troubleshooting
Power Supply
(1)
Power does not turn on when pressing ON/OFF key
・
The battery may not be charged. Charge is performed.
(2)
Power does not turn off when pressing ON/OFF key
・
Press and hold the key until the LED color changes from green to red.
(3)
Few splices can be made with a fully charged battery pack
・
If the power saving function is not enabled, battery power degrades quicker. Always
enable it to conserve power usage.
・
The battery pack has reached the end of its service life. Install a new battery pack.
・
The battery pack uses chemical reaction. The capacity decreases at low temperature,
especially at lower than 0 degree C.
・
At high altitude, the arc discharge current is increased. In this condition, battery power
degrades quicker due to large power consumption.
(4)
“CHARGE” LED on blinks during battery recharge
・
The battery pack has a fault or has reached the end of its service life. Install a new battery
pack. If the LED blinks again after install, contact the authorized distributor.
・
The battery pack has been used under the environment (especially 40 degrees C or more)
where temperature is high, or direct rays.
(5)
Method to change the power saving function settings
・
Refer to [Machine Settings] function.
(6)
Battery indicator is not displayed.
・
At the time of AC adaptor use, a battery indicator is not displayed on a screen.