41S_Rev00
67
Splice Settings Menu
Detail of the Splice Settings parameters
Below is the parameter in Splice Settings.
Splice Settings parameter list
Parameter
Description
Fundamental Settings
Pause
If “Pause” is set to "ON", the splicing operation pauses after fiber
alignment is completed.
Auto Start Trigger
Select of "ON", and "OFF" can be performed for splicing operation.
Splice Memory
Comment
A comment can be added to the memory saved at the time of the
end of connection.
Heater Menu
Auto Start Trigger
Select of "ON", and "OFF" can be performed for heating operation.
Ignore Splicing Error
Loss
Set to “ON” or “OFF”.
Enable : An operator can skip an error shown on the left by
pressing the SET key.
Disable : An operator can’t skip an error shown on the left.
Bubble
Fat
Thin
Cleave
Set to “Enable” or “Disable”.
Enable : An operator can skip an error as shown on the left by
pressing the SET key.
Disable : An operator can’t skip an error as shown on the left. The
unit repeats the alignment when the operator presses
the SET key.
Cleave Shape
Fiber Angle
Others
Auto Fiber
Forward
If “Auto Fiber Forward” is set to “ON”, fibers are automatically moved
closer to gap set as soon as wind protector is closed.
Max Num. of
Rearcs
The re-arcing process sometimes improves the splice loss, but
sometimes worsens it. Re-arcing decreases the splice strength.
With this function, it is possible to limit the number of re-arcs or to
disable re-arc discharge.
Cleave Counter
Mode
When splicing, the splice increments the “Cleave Count”.