41S_Rev00
65
Heater Menu
Detail of the parameters in heater mode
Below is a list of Heating parameters.
Heater mode parameters
Parameter
Description
Sleeve type
Sets sleeve type. List of all heating modes are displayed. Select a mode in
the list and this is copied to a user-programmable mode.
Mode Title1
Title of a heater mode that is displayed in the lower right part of the monitor
during the splicing/heating process. Max number of characters used is 7.
Mode Title2
Description of a heater mode in the [Sleeve Type] screen. Max number of
characters used is 15.
Heat Time
Sets heating time from the beginning to the end (cool-down completion).
Heating time is automatically adjusted with atmospheric conditions, such as
ambient temperature. Heating time may be longer or shorter than [Heat
time] set.
Heat
Temperature
Sets heating temperature.
Finish
Temperature
Sets the finish temperature. The buzzer beeps after completion of the
heating.
Caution
Do not touch the shrunken sleeve after removing the fiber from the tube
heater. It may be hot. Hot sleeves easily deform and can cause some
residual stress at the splice point. Use J-plate to cool down the sleeve.
About heating of a connector splice part
The heater of this splicer corresponds to connector.
It can be used for connectors from other companies by lifting the rubber plate up as shown
below figure. The heating operation can be performed easily.
When using Fujikura Fuse Connect, removing the clamp is unnecessary.
Heating contraction work can be done in the usual state.
*The sleeve position may need to be shifted prior to heating.
Rubber plate