V-301 series Operating Instructions Ver1.02E
21
1 1 Remove the teflon sheet. (Refer to " Slide
the teflon sheet" in page 20.)
2 Loosen the screw A on the right and left
electrodes and remove the terminal cover.
3 Loosen the screw B to release the tension
of heating element.
(No need to remove the electrode cover.)
4 Insert Phillips screwdriver into the hole on
the electrode and loosen the screw C.
Heating element can be removed.
5 When attach the new heating element,
insert the heater's terminal one by one
between the plate spring and electrode.
Fasten the screw C while holding the
heating element down wiith your finger to
make sure that it doesn't slip from
position.
6 Fasten the screw B tightly so that the
heating element is pulled to both ends.
(If it wouldn't be tensioned, heating
element may be damaged.)
7 Attach the terminal cover by fastening
screw
1 Remove the teflon sheet. (Refer to "Slide
the teflon sheet" in page 20 .)
2 Loosen the screw B to release the tension
of heating element.
(No need to remove the electrode cover.)
3 Insert Phillips screwdriver into the hole on
the electrode and loosen the screw C.
Heating element can be removed.
4 When attach the new heating element,
insert the heater's terminal one by one
between the plate spring and electrode.
Fasten the screw C while holding the
heating element down with your finger to
make sure that it doesn't slip from
position.
5 Fasten the screw B tightly so that the
heating element is pulled to both ends.
(If it wouldn't be tensioned, heating
element may be damaged.)
● Lower section (for V-301, V-301-10D)
● Upper section (for V-301-10D)
Teflon sheet
Heating element
Turn
Screw B
Teflon sheet
Heating element
Screw C
Push and turn the screw with
incleded Philips screwdriver
Screw B
Turn
Heating element
Push and turn the screw with
incleded Philips screwdriver
Screw C
Heating element
Glass tape (13mm)
(to be pasyes on the heating
element)
Caution
If the screw B is not loosened,
heating element is kept the
tension, and terminal of heating
element cannot be set between
the plate spring and electrode.
Caution
If the screw B is not loosened,
heating element is kept the
tension, and terminal of heating
element cannot be set between
the plate spring and electrode.