background image

Enthermics Medical Systems

 

An ISO 13485:2003 certified company

W164 N9221 Water St  |  Menomonee Falls WI 53051

Tel 262-251-8356  |  800-TO-B-WARM

generalinfo@enthermics .com

www .enthermics .com

Printed in the U.S.A.

Specifications are subject to change without notice.

Made in the U.S.A.

Owner’s Manual

MN-39362  •  Rev 0  •   04/18

Titan Series Combination  

Blanket/Fluid Warmer

EC1850BL

Summary of Contents for EC1850BL

Page 1: ... Menomonee Falls WI 53051 Tel 262 251 8356 800 TO B WARM generalinfo enthermics com www enthermics com Printed in the U S A Specifications are subject to change without notice Made in the U S A Owner s Manual MN 39362 Rev 0 04 18 Titan Series Combination Blanket Fluid Warmer EC1850BL ...

Page 2: ...ration Instructions Preparation Before Operating the Warmer 10 Using the Blanket Controller 11 Operating the Blanket Chamber 12 Using the Fluid Controller 13 Operating the Fluid Chamber 15 Cleaning and Preventative Maintenance 16 Preventative Maintenance Checklist 17 Dimension Drawings 18 Troubleshooting 20 Service 22 Wire Diagram 31 Authorized Representative MDSS GmbH Schiffgraben 41 30175 Hannov...

Page 3: ... if the package has been damaged or opened All Enthermics Medical Systems appliances are sold Free on Board F O B shipping point and when accepted by the carrier such shipments become the property of the consignee Should damage occur in shipment do not put the appliance into service until the damage has been inspected by an authorized service provider Should damage occur in shipment it is a matter...

Page 4: ...can move or roll on uneven floors Attention Due to the size and weight of the warming cabinet additional moving equipment fork lift dolly etc will be needed to lift and move the warming cabinet and packaging materials Make appropriate plans when moving the warming cabinet Dimensions HxWxD With casters 74 8 x 30 0 x 28 0 1900mm x 762mm x 712mm Capacity Fluid compartment 30 1 liter bottles or 24 1 l...

Page 5: ...ead and understood by all operators and users Any troubleshooting guides component views and parts lists included in this manual are for general reference only and are intended for use by qualified and trained technicians This manual should be considered a permanent part of this appliance This manual and all supplied instructions diagrams schematics parts lists notices and labels must remain with t...

Page 6: ...ndard Fluid chamber capacity 30 1 liter bottles or 24 1 liter bags Blanket chamber capacity 30 blankets 16 4 ft3 Control Adjustable temperature range Blanket chamber has an adjustable temperature range of 32 C 71 C 90 F 160 F Fluid chamber can be programmed to warm either irrigation fluids IRR or injection fluids INJ with separate temperature ranges provided depending on the choice selected IRR temp...

Page 7: ...t 30 1 liter bottles or 24 1 liter bags Blanket compartment 30 40 blankets 16 4 ft3 Weight Net 457 lbs 207 kg Ship 568 lbs 258 kg Shipping dimensions 38 L x 38 W x 90 H Electrical 120 VAC 50 60 Hz 1 ph 1 3 kW 11 0 Amps Safety Class I Equipment No Applied Parts Mode of Operation Continuous NEMA 5 20P 20A 125V Plug Hospital Grade IP X0 E471516 220 VAC 50 60Hz 1 ph 1 2 kW 5 5 Amps Type B Equipment CE...

Page 8: ...tended for use in the electromagnetic environment specified below The customer or the end user of this appliance should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electromagnetic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors ar...

Page 9: ...electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the appliance is used exceeds the applicable RF compliance level above the appliance should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating...

Page 10: ... clean lint free cloth 2 Clean the interior and exterior of the warmer with a mild soap and water solution Apply the solution with a clean damp cloth Do not use commercial or household cleaners that contain ammonia NOTE Make sure to wipe the control panel door vents doorhandle or door button and door gaskets 3 Remove all detergent residue from the interior and exterior of the warmer with a clean d...

Page 11: ...ure recall button 1 The temperature at the compartment sensor is displayed 2 for five 5 seconds Then the blanket chamber temperature set point is displayed How to Lock the Controller The controller can be locked to prevent changes being made to the temperature set point or the mode selection 1 Press the ON OFF button 4 and the up arrow button 3 simultaneously The lock icon 7 illuminates How to Unlo...

Page 12: ...ate the circuit breaker at the back of the warmer 3 Push the circuit breaker to the ON I position 4 Press the ON OFF button 4 The previous temperature set point is displayed 2 5 Press the up arrow button 3 or down arrow button 5 to adjust the temperature set point 2 The temperature set point range is 32 C to 71 C 90 F to 160 F NOTE Cool the chamber prior to changing from a higher temperature setti...

Page 13: ...the previous temperature set point is displayed 2 How to Set the Operational Sound Volume 1 While the fluid controller is on press the temperature recall button 1 and the down arrow button 7 simultaneously The current sound volume setting is displayed 2 2 Press the up arrow button 5 or the down arrow button 7 to change the volume Volume settings range from 0 mute to 12 loud NOTE The alarm volume is...

Page 14: ...sounds an alarm and the alarm icon 10 flashes 1 Press the ON OFF button 6 to acknowledge and mute the alarm NOTE If the alarm continues or reoccurs the warmer needs to be serviced Power Fail Detection The controller stores all settings and resumes operation using these settings in the event of a power failure When the power is restored the controller sounds an alarm once The LED screen 2 flashes 1 P...

Page 15: ...event an unwanted alarm 6 Make sure the fluid chamber insert is installed 7 Load the fluid chamber with appropriate fluid containers 8 Make sure the warmer door is securely closed after initial loading and following each fluid removal Operating the Fluid Chamber CAUTION This appliance is not approved for warming blood or blood products WARNING Verify the fluid temperature prior to using the fluid Refe...

Page 16: ...o Clean the Appliance 1 Disconnect the appliance from the power source 2 Remove and wash any detachable items such as the support assembly with hot soapy water Dry with a clean lint free cloth 3 Clean the interior and exterior of the appliance with a mild soap and water solution Apply the solution with a clean damp cloth Do not use commercial or household cleaners that contain ammonia NOTE Make su...

Page 17: ...liance Clean the interior Ensure that the controller LEDs illuminate Ensure that the interior LED illuminates if applicable Inspect the fluid insert assembly for damage or missing pieces Inspect the blanket support assembly and the shelf for damage or missing pieces Ensure that the assemblies are installed Daily Checklist Is the operation and care manual available Has everyone been trained in the o...

Page 18: ...ke Clearance requirements 4 102mm from rear 1 25mm from top 2 51mm from sides 1 2 13mm from bottom 74 8 1900mm 68 0 1727mm 30 0 762mm 15 0 381mm CAVITY INSERT 26 5 673mm CAVITY 23 6 598mm INSERT 36 0 914mm CAVITY 35 0 890mm INSERT 23 6 598mm INSERT 58 6 1488mm 29 2 742mm 55 3 1405mm 26 5 673mm 28 0 712mm 49 5 1256mm IEC Cord Inlet 23 6 599mm CAVITY 23 6 599 44mm CAVITY ...

Page 19: ...ings EC1850BL with feet 69 1743mm 68 1 1729mm 30 0 762mm 15 0 381mm CAVITY INSERT 26 5 673mm CAVITY 23 6 598mm INSERT 36 0 914mm CAVITY 35 0 890mm INSERT 23 6 598mm INSERT 58 6 1488mm 29 2 742mm 55 3 1405mm 26 5 673mm 28 0 712mm 43 3 1100mm IEC Cord Inlet 23 6 599mm CAVITY 23 6 599 44mm CAVITY ...

Page 20: ...re proper and secure connections If necessary re secure the faulty connections Call service if error persists E 11 ES11 ES21 ES31 ES41 ES51 ES61 ES71 Cavity sensor Pad sensor 1 Pad sensor 2 Pad sensor 3 Pad sensor 4 Pad sensor 5 Pad sensor 6 Pad sensor 7 Sensor is open Software disengages heating pads Acknowledge error by pressing the ON OFF button If error persists a qualified service technician s...

Page 21: ... error persists a qualified service technician should test the sensor Test the sensor Detach the sensor from the warmer Use an Ohm meter to measure the resistance of the sensor Check the sensor at 25 C 77 F If the reading is 10 KOhm 1 5 KOhm replace the display If the reading is 2 KOhm replace the sensor Check the wires for integrity Inspect the connections at the control and terminal block to ensu...

Page 22: ...ectrical shock use only UL listed 20A 250V fast acting fuses 6 3mm x 32mm F1 F2 Access should be made by qualified service technicians only A hospital grade cord must be used Refer to the owner s manual or contact the manufacturer for acceptable cords The warmer must be connected to an equivalent receptacle marked hospital grade 1 Unplug the power cord 1 from the wall outlet and the power inlet 2 ...

Page 23: ...NDOW LH LK 5025411 1 ASSEMBLY DOOR SOLID LH LK 5025431 1 ASSEMBLY DOOR SOLID LH 5025429 1 ASSEMBLY DOOR SOLID RH LK 5025430 1 ASSEMBLY DOOR SOLID RH 5025412 1 6 ASSEMBLY DOOR WINDOW 5025133 1 ASSEMBLY DOOR SOLID 5025433 1 ASSEMBLY DOOR WINDOW LK 5025434 1 ASSEMBLY DOOR SOLID LK 5025435 1 7 PANEL BACK 1024790 1 8 PANEL TOP COVER 1024924 1 9 PANEL TOP TRIM 1024923 1 10 PANEL SIDE RH 1024789 2 11 PAN...

Page 24: ...Combination Blanket Fluid Warmer Service 2 3 4 1 2 3 4 1 Item Description Part Qty 1 PANEL INSERT SIDE FLUID CAVITY 1024771 2 2 PANEL SHELF BOTTOM 1024766 2 3 PANEL INSERT SIDE BLANKET CAVITY 1025073 2 4 PANEL SHELF 1024763 1 EC1850BL Interior View ...

Page 25: ...OARD 4 ZONE 120V BA 39302 2 RELAY BOARD 4 ZONE 230V BA 39304 2 4 CONTROL BOARD CC 36126 2 5 CABLE RELAY BOARD CB 35193 2 6 CABLE 12 DISPLAY CB 38543 2 7 SHUNT CONNECTOR 0 1 PINS CR 36952 1 9 SCREW M3 0 5 x 16MM PHILLIPS HEAD SC 35824 20 10 SCREW M3 0 5 x 30MM PHILLIPS HEAD SC 38668 10 11 SPACER 1 4 DIA x 3 8 NYLON SP 29425 36 12 SCREW M3 0 5 x 30MM PHILLIPS HEAD SC 38128 1 13 BIMETAL SWITCH TT 361...

Page 26: ...on Part Qty 1 SCREW M3 x 0 5 x 10MM PAN SC 22620 2 2 CORD FOR 4 BOX FAN CD 33338 1 3 FAN AXIAL 120MM 100 240V FA 39406 1 4 IEC POWER LINE FILTER FI 38581 1 5 FUSE HOLDER FU 35033 4 6 NUT M4 KEPS ZINC PLATED NU 36319 4 7 PLUG 1 2 HOLE PG 3344 1 8 ROCKER SWITCH SW 34769 1 9 SCREW M4 x 0 7 x 50MM PAN SC 29261 4 EC1850BL Power inlet assembly ...

Page 27: ...mbination Blanket Fluid Warmer Service 1 3 2 4 1 3 2 4 Item Description Part Qty 1 CIRCUIT BOARD FLUID DISPLAY BA 35309 1 2 NUT M3 0 5 HEX NUT NU 22285 8 3 SPACER 1 4 HEX NYLON SP 33707 8 4 CIRCUIT BOARD DISPLAY BA 34868 1 EC1850BL Interface assembly ...

Page 28: ...luid Warmer Service BLANKET AND FLUID CAVITY 3 2 1 4 BLANKET AND FLUID CAVITY 3 2 1 4 Item Description Part Qty 1 FAN AXIAL 120MM 100 240V FA 39406 1 2 FAN GUARD GD 2396 1 3 SCREW M4 x 0 7 x 50MM PAN SC 29261 4 4 NUT M4 KEPS ZINC PLATED NU 36319 4 EC1850BL Fan assembly ...

Page 29: ...nket Fluid Warmer Service 4 3 1 2 4 3 1 2 Item Description Part Qty 1 SCREW M4 x 0 7 x 10MM PAN SC 22273 2 2 SENSOR MOUNTING BLOCK BK 29882 2 3 FLUID CAVITY CAVITY SENSOR 48 WIRE PR 38590 1 4 BLANKET CAVITY CAVITY SENSOR 24 WIRE PR 37140 1 EC1850BL Cavity sensors ...

Page 30: ...30 MN 39362 Rev 0 04 18 Titan Series EC1850BL Combination Blanket Fluid Warmer Wire Diagram Serial number is required for all inquiries Part numbers and drawings are subject to change without notice ...

Page 31: ...85 2003 certified company W164 N9221 Water St Menomonee Falls WI 53051 Tel 262 251 8356 800 TO B WARM generalinfo enthermics com www enthermics com Printed in the U S A Specifications are subject to change without notice Made in the U S A ...

Reviews: