1.Disassembly
[4]
Take out TOP BOARD MYLAR and WIRE FFC
.
[5]
Remove the screws *2
(085-0343-001),
screw *1
(085-0340-001) and
unsolder soldering
joints.
[6]
Take out the PCBA SHUTTER ASSY.
[7]
Remove the screw *2
(085-0340-001), and
unsolder Flash wires.
TOP BOARD
MYLAR
WIRE FFC
PCBA,SHUTTER ASSY
[8]
Take out the TOP BOARD ASSY
[9]
Remove the screws *2
(085-0340-001)
.
TOP BOARD ASSY
[10]
Take out the EVF ASSY
Caution
:
Push the two hook toward inside direction and take out the EVF ASSY carefully.
Don’t damage the EFA ASSY
.
HOOK