Confidential: FUJIFILM Service Center Use Only
3. Adjustments
3-1-2. Adjustment when replacing major parts
Note that the adjustment data will be erased if the adjustment sequence is not followed correctly.
No.
Replacing
parts
MAIN PWB ASSY
LENS CONST
LCD
0 LCD
Adjustment
○
○
1
Firmware Download *
○
2
Module Select
○
3
EFA Adjustment
○
○
4
Shutter Delay Adjustment
○
○
5
ISO DBP Shading Adjustment
○
○
6
RunIn WBP Adjustment
○
○
7
OIS DATA Download
○
○
8
USB ID/LENS DATA Writing
○
○
9
OIS Calibration
○
○
10
Destination Setting
○
★
★
* Always download the firmware after completing the adjustments and replace the adjustment firmware with the project firmware.
3-2. Measuring instruments used
Measuring equipment Remarks
PC
Used for USB ID/LENS DATA Write and operation checks (PC-AT
compatible)OS: Win XP, SP2
Brightness meter
LS-110 (Minolta) or equivalent
Color temperature meter
Color Meter IIIF (Minolta) or equivalent
Pattern box
PTB450F
3-2