3. Adjustments
3-17. OIS Calibration
3-17-1. OIS Test
<STEP
1
>
Copy the "Batch" folder of the "
OIS_Test
" folder, which is stored in the
FxS1700_W
folder, directly under SD card.
* When a "Batch" folder already exists directly under SD card, delete this folder before copying.
Insert the adjustment SD card and the DC COUPLER CP-04 into the camera, and turn power ON.
--> Adjustment software activates.
Condition:
Put the camera on a stable table or ground.
(Don't touch or shake the camera or table when testing.)
<STEP
2
>
Put the camera on the desk, and power on the camera.
(When testing, don’t touch the camera or desk.)
Camera will do “Hall Bias / Hall Gain”, “Gyro Bias” and “Abnormal
Oscillation” calibration automatically.
When LCD displays “Test ok”, the OIS calibration was done. Press
“POWER” button to de-energize the CAMERA.
<Settings for
OIS Calibration
>
3-27