5. Inspection
FinePix A400 Service Manual
5. Inspection
5-1. Required Measuring Equipment
Measuring equipment
Remarks
Power supply
AC adapter (AC-3V), Regurated power supply
Digital voltmeter
For general use
Ammeter
For general use (able to measure 1mA or less)
FxA500/A400 Battery jig
Common with adjustment JIG (ZJ00956-100)
xD-Picture card
For general use
Macro Chart
Resolution confirmation (ZJ00525-100)
TV Monitor
TV monitor, minimum resolution 600 lines
5-2. Connection of Measuring Equipment
Use FxA500/A400 Battery jig.
The output current of the Regurated power supply must not become 3A or more.
FinePix A500/A400
FxFinePix A500/A400
Battery Jig
Ammeter
Summary of Contents for FINEPIX A400
Page 6: ...6 FinePix A400 Service Manual MEMO...
Page 22: ...22 3 Schematics FinePix A400 Service Manual 3 5 Overall connection Diagram...
Page 23: ...23 3 Schematics FinePix A400 Service Manual 3 6 Circuit Diagrams 3 6 1 CAMERA BLOCK...
Page 24: ...24 3 Schematics FinePix A400 Service Manual 3 6 2 DCDC BLOCK...
Page 25: ...25 3 Schematics FinePix A400 Service Manual 3 6 3 MOTOR BLOCK...
Page 26: ...26 3 Schematics FinePix A400 Service Manual 3 6 4 PROCESS BLOCK...
Page 27: ...27 3 Schematics FinePix A400 Service Manual 3 6 5 SUB BLOCK z Revised 22 Sep 2006 z...
Page 28: ...28 3 Schematics FinePix A400 Service Manual MEMO...
Page 29: ...29 3 Schematics FinePix A400 Service Manual 3 6 6 KEY BLOCK...
Page 30: ...30 3 Schematics FinePix A400 Service Manual 3 6 7 LCD BLOCK...
Page 31: ...31 3 Schematics FinePix A400 Service Manual 3 6 8 CCD FPC BLOCK 3 6 9 VIDEO BLOCK...
Page 32: ...32 3 Schematics FinePix A400 Service Manual 3 6 10 MEDIA BLOCK 3 6 11 STRB BLOCK...
Page 33: ...33 3 Schematics FinePix A400 Service Manual 3 7 Mounted Parts Diagrams 3 7 1 CCD FPC ASSY...
Page 34: ...34 3 Schematics FinePix A400 Service Manual 3 7 2 MAIN PWB ASSY SIDE A...
Page 35: ...35 3 Schematics FinePix A400 Service Manual SIDE B...
Page 95: ...26 30 Nishiazabu 2 chome Minato ku Tokyo 106 8620 Japan FUJI PHOTO FILM CO LTD...