7-2
Item
Specifications
Type FRN___LM2A-4
□
0039
0045
0060
0075
0091
Nominal applied motor [kW]
18.5
22
30
37
45
Ou
tp
ut
r
at
in
gs
Rated capacity
*1
[kVA]
29
34
45
57
69
Rated voltage
*2
[V]
Three-phase 380V-480V, 50/60Hz
Rated current
*3
[A]
39.0
45.0
60.0
75.0
91.0
Overload capacity [A]
(Permissible overload time)
78.0
(3s)
90.0
(3s)
120
(3s)
150
(3s)
182
(3s)
Rated frequency [Hz]
50, 60Hz
In
pu
t ra
tin
gs
Ma
in
p
o
we
r
su
pp
ly
No
rm
al
o
pe
ra
tio
n
Phases, Voltage, Frequency
Three-phase, 380 to 480V, 50/60Hz
Variations
Voltage: +10 to -15% (Voltage unbalance: 2% or less
*4
)
Frequency: +5 to -5%
Rated
current
*5
[A]
with DCR
35.5
42.2
57.0
68.5
83.2
Without DCR
52.3
60.6
77.9
94.3
114
Required power supply capacity
(with DCR) [kVA]
25
30
40
48
58
UPS
oper
at
ion
Phases,Voltage,Frequency
Single-phase, 220 to 480V, 50/60Hz
Variations
Voltage: +10 to -10% ,Frequency: +5 to -5%
Operation time [s]
180
Bat
ter
y
oper
at
ion
Power Supply Voltage for driving DC 48V or more in the direct current voltage conversion
Operation time [s]
180
Auxiliary control power supply Voltage
Single-phase
220 to 480V, 50/60Hz
*9
Br
ak
ing
Braking time
*7
[s]
60
Braking duty-cycle (%ED)
*7
[%]
50
Rated regenerative power
*7
[kW]
14.8
17.6
24
29.6
36
Minimum resistance which can be
connected [
Ω
]
*6
16
16
10
8.5
8
EMC filter
Built-in (According to EN12015, EN12016)
Enclosure (IEC60529)
IP20
IP00
Heat sink
IP20
IP00
Cooling method
Fan cooling
Average sound pressure level at trip.[dBA]
*8
55
60
Average power losses [W]
in standstill
*12
26
33
in standby
*13
16
18
Weight/Mass [kg]
10.5
11.2
27
28
32
*1) Rated capacity is calculated by regarding the output rated voltage as 440V .
*2) Output voltage cannot exceed the power supply voltage.
*3) These values correspond to the following conditions: carrier frequency is 10 kHz (2 phase modulation) and ambient
temperature is 45°C.
Select the inverter capacity such that the square average current during operation is not higher than the 80% of the
rated current of the inverter.
*4) Voltage unbalance [%] = (Max.voltage [V] - Min.voltage [V])/ Three-phase average voltage [V] x 67 (IEC61800-3)
*5) The power supply capacity is 500kVA (ten times the inverter capacity when the inverter capacity exceeds 50kVA), and
the value of the power supply impedance is %X=5%.
*6) The admissible error of minimum resistance is
±
5%.
*7) Braking time and duty cycle (%ED) are defined by cycle operation at the rated regenerative power as shown in the
figure below.
0
C yclic period
:T
0
Tim e
[s]
Braking time : T
1
R eated regenerative pow er
%
ED =
×
100
T
1
T
0
R egenerative pow er
[kW]
B raking tim e : T
1