7-4
2) Single-phase 200V series
Item
Specifications
Type FRN___LM2A-7
□
0011
0018
Nominal applied motor [kW]
2.2
4.0
Ou
tp
ut
r
at
in
gs
Rated capacity
*1
[kVA]
4.1
6.8
Rated voltage
*2
[V]
Three-phase 200V-240V, 50/60Hz
Rated current
*3
[A]
11.0
18.0
Overload capacity
*4
[A]
(Permissible overload time)
22.0
(3s)
36.0
(3s)
Rated frequency [Hz]
50, 60Hz
In
pu
t ra
tin
gs
Ma
in
p
owe
r
su
pp
ly
No
rm
al
o
pe
ra
tio
n
Phases, Voltage, Frequency
Single-phase, 200 to 240V, 50/60Hz
Variations
Voltage: +10 to -15% ,Frequency: +5 to -5%
Rated
current
*5
[A]
with DCR
17.5
33
Without DCR
24
41
Required power supply capacity
(with DCR) [kVA]
3.5
6.1
UPS
oper
at
ion
Phases,Voltage,Frequency
Single-phase, 200 to 240V, 50/60Hz
Variations
Voltage: +10 to -10% ,Frequency: +5 to -5%
Operation time [s]
180
Bat
ter
y
oper
at
ion
Power Supply Voltage for driving
DC 36V or more in the direct current voltage conversion.
Operation time [s]
180
Auxiliary control power supply Voltage
DC 24V (22V to 32V) ,Maximum 40W
Br
ak
in
g
Braking time
*7
[s]
60
Braking duty-cycle (%ED)
*7
[%]
50
Rated regenerative power
*7
[kW]
1.8
3.2
Minimum resistance which can be
connected [
Ω
]
*6
33
20
EMC filter
Built-in (According to EN12015, EN12016)
Enclosure (IEC60529)
IP20
Heat sink
IP54
Cooling method
Fan cooling
Average sound pressure level
at trip.[dBA]
*8
44.5
48
Average power losses [W]
in standstill
*12
23
in standby
*13
16
Weight/Mass [kg]
4.1
4.5
*1) Rated capacity is calculated by regarding the output rated voltage as 220V
*2) Output voltage cannot exceed the power supply voltage.
*3) These values correspond to the following conditions: carrier frequency is 10 kHz (2 phase modulation) and ambient
temperature is 45°C.
Select the inverter capacity such that the square average current during operation is;
- For FRN0011LM2A-7: Up to the 80% of the rated current of the inverter.
- For FRN0018LM2A-7: Up to the 70% of the rated current of the inverter.
*4) With DCR. Without DCR, overload capacity is 150%, 3s.
*5) The power supply capacity is 500kVA and the value of the power supply impedance is %X=5%.
*6) The admissible error of minimum resistance is
±
5%.
*7) Braking time and duty cycle (%ED) are defined by cycle operation at the rated regenerative power as shown in the
figure below.
0
C yclic period
:T
0
Tim e
[s]
Braking time : T
1
R eated regenerative pow er
%
ED =
×
100
T
1
T
0
R egenerative pow er
[kW]
B raking tim e : T
1