8-4
8.4.3 Leakage current of the EMC filter
This product has built-in EMC compliant filter that contains grounding capacitors for noise suppression which
increase the leakage current. Check whether there is no problem with electrical systems. When using this
product, the leakage current listed in Table 8.2 is added. Before adding this product, consider whether the
additional leakage current is allowable in the context of the overall system design.
Table 8.2 Leakage Current of FRENIC Lift
Input power
Inverter type
Leakage
current (mA)
Input power
Inverter type
Leakage
current (mA)
Three-phase
400 V
FRN0006LM2A-4
□
15
One-phase
200 V
FRN0011LM2A-7
□
15
FRN0010LM2A-4
□
FRN0018LM2A-7
□
FRN0015LM2A-4
□
FRN0019LM2A-4
□
FRN0025LM2A-4
□
FRN0032LM2A-4
□
FRN0039LM2A-4
□
3
FRN0045LM2A-4
□
FRN0060LM2A-4
□
8
FRN0075LM2A-4
□
FRN0091LM2A-4
□
* Calculated based on these measuring conditions
400V series: 400V, 50Hz with neutral grounding, and an interphase voltage unbalance ratio of 2%.
200V series: 230V, 50Hz with phase grounding.
Note:
A box (
o
) replaces an alphabetic letter depending on the shipping destination.
o
Shipping destination: E (Europe) or A (Asia)