2-6
(2) Arrangement of control circuit terminals
Table 2.3 Control Circuit Terminals
Connection method with shield plate of CANopen terminal.
Terminal block type
Screw specifications
Recommended
wire size (mm
2
)
Type of screwdriver
(tip shape)
Wire strip length
Screw
size
Tightening
torque
Relay terminals
M2.5
0.39
±
10% N
·
m
0.20 to 3.31 mm
2
(AWG24 to 12)
Flat screwdriver
(0.4 mm x 3.0mm)
6mm
Other
M2
0.19
±
10% N
·
m
0.20 to 1.31 mm
2
(AWG24 to 16)
Flat screwdriver
(0.4 mm x 2.5 mm)
6 mm
Tightwire
Tightwire
Tightwire
(FRN0011LM2A-7
□
/
FRN0018LM2A-7
□
)
(FRN0006LM2A-4
□
to
FRN0032LM2A-4
□
)
(FRN0039LM2A-4
□
/
FRN0045LM2A-4
□
)
(FRN0060LM2A-4
□
to
FRN0091LM2A-4
□
)