12
5.4 Setting of parameters
• Units are displayed in metric system.
5.4 (1) Setting of piping specifications
Description
Set the data of pipe required for measurement. The mounting dimension of the sensor is
automatically calculated. Data of each item should be entered according to the display.
Item
Outside diameter of pipe
Material of pipe
Pipe wall thickness
Lining (with/without)
and material
Type of fluid
Dynamic viscosity
coefficient of fluid
Mounting method of
sensor
Type of sensor
Transmission voltage of
sensor
Entry
Numeric value
Selectable
Numeric value
Selectable
Selectable
Numeric value
Selectable
Selectable
Selectable
Range or menu
2 in. to 236 in.
CARBON STEEL, STAINLESS STEEL, PVC,
COPPER, CAST IRON, ALUMINUM, FRP, ASBES-
TOS, DUCTILE IRON, PEEK, PVDF, ACRYLIC,
OTHERS*1
0.0039 in. to 3.937 in.
NO LINING, TAR EPOXY, MORTAR, RUBBER,
TEFLON, PYREX GLASS, OTHERS *1
WATER, SEAWATER, OTHERS *1
0.001E-19.68 ft.
2
/s to 999.999E-19.68 ft.
2
/s *2
V METHOD, Z METHOD
FLW12, FLW41, FLW50
1 TIME, 2 TIME, 4 TIME, 8 TIME
*1) Selection of “OTHERS”
Materials of piping and lining should be selected within the range of 3281 to 12,139 ft./sec.
of sound velocity and 1640 to 8202 ft./sec. of flow velocity (see Appendix).
*2) Dynamic viscosity coefficient is expressed in water (68
°
F: 1.004E-19.68 ft.
2
/s)
When more accurate data need be obtained or fluid other than water is selected, enter an
appropriate data as needed from Appendix.