43
8-4 NO DC OUTPUT
8-4-1 CHECK THE AC OUTPUT.
Check the generator by following Step 8-1-1 through Step 8-1-2.
8-4-2 CHECK THE DC BREAKER.
If the DC breaker turned off while charging a
battery, check the cables for short-circuit or
connection in reverse polarity before resetting
it.
NOTE: If the DC output is used to charge
a large capacity battery or an over
discharged battery, an excessive
current may flow causing.
8-4-3 CHECK THE WIRING.
Check all the wires to be connected correctly.
8-4-4 CHECK THE DIODE STACK.
Remove the end cover and check the diode
stack with a circuit tester.
Refer to Section 6-7
“
DIODE STACK
”
for the
checking procedure.
8-4-5 CHECK THE DC COIL
Check the resistance between two Brown leads from stator with a circuit tester.
If the resistance reading is much larger or smaller than the specified value, the DC coil of the
stator is faulty. Replace stator.
9. WIRING DIAGRAM
RGX6500, 7500
Summary of Contents for ROBIN RGX6500
Page 1: ...1 RGX6500 RGX7500 FUJI HEAVY INDUSTRIES LTD...
Page 2: ...2...
Page 3: ...3 1 SPECIFICATIONS...
Page 4: ...4 2 PERFORMANCE CURVES RGX6500 60Hz 240V RGX7500 60Hz 240V...
Page 5: ...5 3 GENERAL DESCRIPTION Canister...
Page 6: ...6 CONTROL PANEL 50Hz 220V 240V 60Hz 220V 240V 60Hz 110 220V...
Page 7: ...7 SERIAL NUMBER CONSTRUCTION RGX6500 RGX7500 Isolator Slip Ring Through Bolt...
Page 11: ...11 5 MEASURING PROCEDURES...
Page 12: ...12...
Page 27: ...27 4 Remove the stator cover Bushing...
Page 44: ...44 50Hz 220V 50Hz 240V 60Hz 220V 60Hz 240V RGX6500 7500 Electric starter model...
Page 45: ...45 50Hz 220V 50Hz 240V 60Hz 220V 60Hz 240V RGX6500 7500...
Page 46: ...46 60Hz 110 220V RGX6500 7500 Electric starter model...
Page 47: ...47 60Hz 110 220V ISSUE EMD GSxxxx Ver 1...
Page 48: ...48...