WWW.FUHR.DE
12
834
autotronic
881
multitronic
2 sec.
2 sec.
2 sec.
4 sec.
10 sec.
10 sec.
In the case of the user-fi nger having been tuned in several times, this also must be deleted
again several times.
Due to the fact that there is always a residual risk when deleting individual fi ngerprints that
the user doesn’t carry out the delete process properly, we generally recommend deleting all
fi ngerprints via the software reset with the aid of the master-fi nger in compliance with the
instructions on page 14, chapter 7.3!
After this new master- and user-fi ngers are tuned in.
5.4 Deleting individual user-fi ngers
Previously tuned-in user-fi ngers can be deleted with the aid of your master-fi nger. To do so, proceed as follows:
1.
Swipe the channel’s master-
fi nger over the line-scanner for
whatever user-fi nger you wish
to delete. The red and green LED
light up at the same time for 2
seconds.
2. Swipe the same master-fi nger
again
within 10 seconds
over
the line-scanner. The red LED
begins to fl ash, the green LED
lights up for 2 seconds.
3.
Now swipe the user-fi nger
to be deleted over the line-
scanner
within 10 seconds
.
The red LED continues to fl ash,
the green LED lights up for
4 seconds.
1. In order to complete the delete
process, swipe the master-fi nger
again across the line-scanner.
The red and green LED light up at
the same time for 2 seconds.
2.
Final test: In order to make
sure that the user-fi nger has
been deleted, swipe it properly
across the scanner once again.
3. If the red LED lights up, the de-
lete process has been carried out
successfully, otherwise please re-
peat the delete process.